Asenware Fire Alarm Smoke Detector
Asenware Fire Alarm Smoke Detector
Asenware Convectional Fire Alarm Smoke Detector, uses a state-of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with the most conventional fire alarm panel. Operating Voltage Range: 9 to 28 VDC Non-polarized Standby Current: ≤120uA@24VDC Maximum Alarm Current(LED on): ≤15mA@24VDC (1K Ohm current-limiting resistance) Operating Humidity Range: ≤95%RH(40℃±2℃)Relative Humidity, Non-condensing Operating Temperature Range: -10℃ to 50℃(14ºF to 122ºF) Smoke Alarm Sensitivity: 0.1-0.15dB/m Height: 48.2mm installed in Base Diameter: 99.45mm Standard Number ref: EN 54-7:2000 EC certificate: 0832-CPR-F2071
KSh 1,200.00Asenware Fire Alarm Smoke Detector
KSh 1,200.00 -
Asenware Conventional Heat Detector
Asenware Conventional Heat Detector Two leds on each detector provide a local 360° visible alarm indication. They die out when the ambient temperature does not reach alarm value. If the temperature reaches the alarm value, then the detector enters to alarm mode and leds light.
KSh 1,300.00Asenware Conventional Heat Detector
KSh 1,300.00 -
Battery Standalone Smoke Detector
Battery Standalone Smoke Detector
The detector is a photo-detector that uses the most advanced optical sensing chamber. It is designed to provide open area protection without wiring, and it is easy to install and construct.
KSh 1,400.00Battery Standalone Smoke Detector
KSh 1,400.00 -
Conventional Manual Call Point With Indicator AW-CMC2166-5
AW-CMC2166-5 Manual Call Point With Indicator installed in public places, when people confirm the fire broke out, pressing the button on the plexiglass sheet, it will send a signal to the fire alarm control panel, after the fire alarm control panel receives the alarm signal, showing that the number or location of the alarm button and the alarm sound.
KSh 1,500.00 -
Conventional Fire Strobe Sounder
Fire Strobe Sounder is a kind of terminal device for alarm; it is used for the sound and light alarm when the fire happens
KSh 1,700.00Conventional Fire Strobe Sounder
KSh 1,700.00 -
Asenware Standalone Heat Detector
Asenware Standalone Heat Detector
This detector is a heat detector that uses the heat runner with the best heat transfer sensitivity. It is designed to provide open area protection without wiring. The red LED on the detector provides a local 360°visible alarm indication. They flash once every minute, indicating that the power is on and the detector is working. When an alarm occurs, the red LED is on, until the temperature is lower than the alarm threshold.
KSh 1,700.00Asenware Standalone Heat Detector
KSh 1,700.00 -
Keyguard Emergency Key Box
Keyguard Emergency Key Box
Keyguard is a purpose designed plastic box to which a clear plastic window is fitted in order to retain a key or access control card. A recess enables the window to be removed in an emergency to retrieve the key
KSh 2,000.00Keyguard Emergency Key Box
KSh 2,000.00 -
Conventional Fire Strobe Sounder AW-CSS2166-5
Conventional Fire Strobe Sounder – AW-CSS2166-5
The AW-CSS2166-5 is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire. By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue. In the event of fire, the device can send out an effective warning sound & flash to notify people to evacuate.
KSh 2,100.00Conventional Fire Strobe Sounder AW-CSS2166-5
KSh 2,100.00 -
Asenware Fire Bell
Asenware Fire Bell is the fire alarm, a fire alarm device, generally used by more staff in public areas. In the event of an emergency situation is controlled by the alarm controller to trigger an alarm, one for each region under normal circumstances, be used for fire alarms, and suitable warning sound effects.Â
KSh 3,400.00Asenware Fire Bell
KSh 3,400.00 -
2 Core Fire Resistant Alarm Cable 1.5mm 100m
Two Core Fire Alarm Cable 1.5mm is designed to resist the spread of fire into a new area. Fire-resistant or fire-rated cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions.
KSh 5,800.002 Core Fire Resistant Alarm Cable 1.5mm 100m
KSh 5,800.00 -
Asenware 2 Zone Conventional Fire Panel
Asenware 2 Zone Conventional Fire Panel; The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
KSh 13,500.00Asenware 2 Zone Conventional Fire Panel
KSh 13,500.00 -
Asenware 4 Zone Conventional Fire Panel
1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3 It has 2 level control mode by a lock
4 It has 24VDC and 5VDC power supply output.
5 It has FIRE and FAULT signal output.
6 It has 2 general sounders output.
7 Each zone has 1 circuit detectors input.
8 Each zone can be disable by a button.
9 It has RESET button to reset the panel.
10 It has SILENCE button to stop BUZZER and SOUNDERS.
11 It has EVACUATE button to start a manual fire alarm immediately.
12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13 It has an optional GSM module for fire alarm by SMS.
14 It is economic, user-friendly and easy maintenance.KSh 16,500.00Asenware 4 Zone Conventional Fire Panel
KSh 16,500.00 -
Asenware 8 Zone Fire alarm control Panel
Asenware 8 Zone Fire alarm control Panel
- It is modularized design, the panel can expend from 1 zone to 32 zones easily.
- It has 2 level control mode by a lock
- It has 24VDC and 5VDC power supply output.
- It has FIRE and FAULT signal output.
- It has 2 general sounders output.
- Each zone has 1 circuit detectors input .
- Each zone can be disable by a button.
- It has RESET button to reset the panel.
- It has SILENCE button to stop BUZZER and SOUNDERS.
- It has EVACUATE button to start a manual fire alarm immediately.
- It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
KSh 21,500.00Asenware 8 Zone Fire alarm control Panel
KSh 21,500.00